Provide Feedback < Back to Support Search SUSE Support Forums Get your questions answered by experienced Sys Ops or interact with other SUSE community experts. Possible Cause: You are trying to run two POAs on the same server and you have not given them unique IMAP port numbers. Possible Cause: You are trying to run two POAs on the same server and you have not given them unique LDAP port numbers. An asterisk denotes a third-party trademark. this contact form

Explanation: Cannot open protocol. Please use the User Comment feature at the bottom of each page of the online documentation, or go to www.novell.com/documentation/feedback.html and enter your comments there. Action: Reboot the server. 850F Connection no longer valid Source: GroupWise engine; general communication. Change the LDAP port for one of the POAs. 6.0 C xxx Engine Error Codes C00x Errors C01x Errors C02x Errors C03x Errors C04x Errors C05x Errors C06x Errors C07x Errors http://www.novell.com/documentation/gw7/gw7_tsh1/data/a4ehiyt.html

Action: Check the CAP port for each POA object. Explanation: Connection was broken while in use. Explanation: A packet of information received by an agent was not in the expected format. GroupWise 7 Troubleshooting 1: Error Messages This Novell® GroupWise® 7 Troubleshooting 1: Error Messages guide covers error messages that appear in ConsoleOne®, GroupWise agents, and GroupWise clients, along with possible causes

Erno is a regular speaker at conferences like Brainshare, GroupWise Summits, and NUI events. He has published several articles in GroupWise Advisor Magazine.Bibliographic informationTitleNovell GroupWise 7 Administrator Solutions GuideNovell PressAuthorTay KratzerPublisherPearson Education, 2005ISBN0672332779, 9780672332777Length936 pagesSubjectsComputers›Data Transmission Systems›GeneralComputers / Data Transmission Systems / General  Export CitationBiBTeXEndNoteRefManAbout Google By using our services, you agree to our use of cookies.Learn moreGot itMy AccountSearchMapsYouTubePlayNewsGmailDriveCalendarGoogle+TranslatePhotosMoreShoppingFinanceDocsBooksBloggerContactsHangoutsEven more from GoogleSign inHidden fieldsBooksbooks.google.co.uk - Novell GroupWise 7 Administrator Solutions Guide is the authoritative guide for It could be something like a bad network card or a problem with dial-up software. 8568 HTTP port already in use Source: GroupWise engine; general communication.

An enhancement request has been submitted 7001853 - GroupWise POA log - Tracking Proxy Access 7001888 - Changing options for the GW Monitor Agent object in ConsoleOne corrupts the GWMONITOR.CFG file Skip to end of metadata Created by MyJH Admin, last modified on May 21, 2009 Go to start of metadata o  Check to see if caps are off o  If caps are off, Possible Cause: A TCP/IP packet was damaged in transit. He has supported Novell GroupWise for 12 years, is a Novell Master CNE, and is the recipient of the Software Support Professional Association's Year 2000 "Outstanding Superstar" award.

See Creating a POA Object in eDirectory in Post Office Agent in the GroupWise 7 Administration Guide . 8562 Client/server request packet contained invalid identifier Source: GroupWise engine; general communication. Please try the request again. The default TCP port used by the POA (1667) is in use by another program. Possible Cause: You are trying to run two POAs on the same server and you have not given them unique HTTP port numbers.

Action: Check your system security. https://www.novell.com/documentation/gw7/gw7_tsh1/data/hrndy328.html A.0 Documentation Updates This section lists updates to GroupWise 7 Troubleshooting 1: Error Messages that have been made since the initial release of GroupWise® 7. Action: Check the HTTP port for each POA object. Action: See 8562 Client/server request packet contained invalid identifier 8567 Data not in BCEF format Source: GroupWise engine; general communication.

Explanation: The HTTP port used by the POA for its Web console is already in use by another program on the server. http://fileupster.com/groupwise-error/groupwise-error-601.html Your cache administrator is webmaster. Datenschutzrichtlinie lesen Erforderliche Felder* X SUSE Support My Favorites Close Please login to see your favorites. Action: None. 8563 Client/server request packet contained invalid identifier Source: GroupWise engine; general communication.

Action: Configure TCP/IP on the server correctly. For technical services and file updates, see Novell Support. This has been resolved in GroupWise 8 Hot Patch 1 7002510 - MSIEXEC.EXE error upon updating from GroupWise 7.03 to GroupWise 8.0 7002514 - Sending mail by nickname will not add navigate here Documentation Updates For the most recent version of GroupWise 7 Troubleshooting 1: Error Messages, visit the GroupWise 7 Documentation Web site.

Explanation: The IMAP port used by the POA to communicate with IMAP e-mail clients is already in use by another program on the server. See Using Client/Server Access to the Post Office in Configuring the POA in the GroupWise 7 Administration Guide . Within each dated section, the updates are listed by the names of the main table of contents sections.

Action: Check the LDAP port for each POA object.

Join Our Community Support Resources Learn how to get the most from the technical support you receive with your SUSE Subscription, Premium Support, Academic Program, or Partner Program. How long will it exist in the temporary location? 7003021 - Support of GroupWise WebAccess on Internet Explorer 8 (IE8) 7003026 - ERROR: "Invalid Index number" while deteting an user account The information helps you to keep current on documentation updates and, in some cases, software updates (such as a Support Pack release). Materials are provided for informational, personal or non-commercial use within your organization and are presented "AS IS" WITHOUT WARRANTY OF ANY KIND.

Action: Exit and restart GroupWise when the machine is back up. 8555 Port in use Source: GroupWise engine; general communication. The TCP port is already in use by another process. Action: Check the SOAP port for each POA. his comment is here Action: Check the TCP port for each POA object.

Explanation: Cannot open connection to specified address. Access to this library has been enabled by Web Publisher (0xDB50)7004436 - Signature added at the end of the mail and not at the end of the reply7004454 - Error: "Unable Explanation: The SOAP port used by the POA to communicate with SOAP clients is already in use by another program on the server. Please contact your system administrator"7004485 - ConsoleOne crashes on SLES 117004492 - In GroupWise Information, what's the difference between Users and Total Mailboxes?7004509 - "Disk is Full" error when opening an

Explanation: The LDAP port used by the POA is already in use by another program on the server. See Using Client/Server Access to the Post Office in Configuring the POA in the GroupWise 7 Administration Guide . See Supporting SOAP Clients in Configuring the POA in the GroupWise 7 Administration Guide . See Using POA Startup Switches in Post Office Agent in the GroupWise 7 Administration Guide .

Vertrieb:+49-911-74053-779 Support:420-28-408-4051 Stets das Neueste erfahren Feedback-Formular We adapt, you succeed. See Providing LDAP Authentication for GroupWise Users in Configuring the POA in the GroupWise 7 Administration Guide . Possible Cause: You are trying to run two POAs on the same server and you have not given them unique CAP port numbers. Action: To enable TCP/IP communication, configure the POA for ConsoleOne.

Environment Novell GroupWise 8Novell GroupWise 8 Hot Patch 1Novell GroupWise 8 Hot Patch 2Novell GroupWise 8 Support Pack Situation Here is a current list of known issues with, and information for,GroupWise When a startup switch can be written with a forward slash for some platforms or a double hyphen for other platforms, the startup switch is presented with a forward slash. Possible Cause: You are trying to run two POAs on the same server in client/server mode and you haven’t created a second POA object in ConsoleOne. There was no need for a fix in GroupWise 8 7001982 - Reply or Forward contains only the Message Header or partial text 7001999 - Archive Directory UNC path locked in